Technical specifications

The philosophy of Styropan is that the quality of its products must not only be high but also certified. From this point of view, Styropan is certified according to the ISO 9001 standard and its thermal insulation products are certified according to the EN 13163 (EPS) and the EN 13164 (XPS) standards. The conformity evaluation is carried out according to the EN 13172 and based on the Initial Type Test (ITT) as well as the factory production control (FPC). Before our products reach the market, they undergo constant and detailed controls to ensure their high and constant quality.

Technical terms explanation of the following board:

  1. λD: Declared value of thermal conductivity
  2. RD: Declared value of thermal resistance
  3. TR: Declared value of thermal resistance
  4. XPS: Extruded polystyrene

 

  1. λD: Declared value of thermal conductivity
  2. TR: Declared value of thermal resistance

 

 

For thicknesses from 20 to 100 mm the technical characteristics of the following table apply:

 
XPS
R&F
Thickness d (mm)   30 40 50 60 70 80 100
λD (W/m*k) 0,033 0,034
RD (m2*k/W)   0,90 1,20 1,50 1,81 2,05 2,35 2,90
XPS
WALL
Thickness d (mm)   30 40 50 60 70 80 100
λD (W/m*k) 0,033 0,034
RD (m2*k/W)   0,90 1,20 1,50 1,81 2,05 2,35 2,90
XPS
WS
Thickness d (mm)   30 40 50 60 70 80 100
λD (W/m*k) 0,033 0,034
RD (m2*k/W)   0,90 1,20 1,50 1,81 2,05 2,35 2,90
XPS
ETICS
Thickness d (mm) 20 30 40 50 60 70 80 100
λD (W/m*k) 0,033 0,034
RD (m2*k/W) 0,60 0,90 1,20 1,50 1,81 2,05 2,35 2,90
XPS
HCS
Thickness d (mm)
50 75 100
λD (W/m*k)
0,033 0,034 0,034
RD (m2 *k/W)
1,50 2,20 2,90
XPS
PR
Thickness d (mm)
30 40 50
λD (W/m*k)
0,033 0,033 0,033
RD (m2 *k/W)
0,90 1,20 1,50
XPS
COMPOSITE PANELS
Thickness d (mm)*
42,5 52,5 62,5 72,5 82,5 92,5
λD (W/m*k)
- - - - - -
TR (m2*k/W)
0,95 1,25 1,55 1,85 2,10 2,40
XPS
DP
Thickness d (mm)
20 21 22
λD (W/m*k)
0,033 0,033 0,033
RD (m2 *k/W)
0,60 0,60 0,65

 

 * These values correspond to the total thickness of the composite panel (12,5 mm gypsum plasterboard plus the XPS panel which is 30/40/50/60/70/80 mm).

 

For the new available thicknesses (120 & 140 mm) the technical characteristics of the following table apply:

 

XPS
R&F
Thickness d (mm) 120 140
λD (W/m*k) 0,034
RD (m2*k/W) 3,50 4,10
XPS
WALL
Thickness d (mm) 120 140
λD (W/m*k) 0,034
RD (m2*k/W) 3,50 4,10
XPS
WS
Thickness d (mm) 120 140
λD (W/m*k) 0,034
RD (m2*k/W) 3,50 4,10
XPS
ETICS
Thickness d (mm) 120 140
λD (W/m*k) 0,034
RD (m2*k/W) 3,50 4,10

 

XPS R&F λD (W/m*k)=0,033
XPS WALL λD (W/m*k)=0,033
XPS WS λD (W/m*k)=0,033
XPS ETICS λD (W/m*k)=0,033
XPS HCS λD (W/m*k)=0,033
XPS PR λD (W/m*k)=0,033
XPS COMPOSITE PANELS TR (m2 *k/W)=2,40
XPS DP λD (W/m*k)=0,033

 

For more info about the technical specifications of the Styropan EPS thermal insulation products, for declarations of performance (DOP), certificates and technical brochures please contact us:

 